ACI A/RH5-R-LCD-010, Room Humidity
Price: $ 88.00
4.6(649)
Buy Now! ACI A/RH5-R-LCD-010 : Room Relative Humidity Sensor, 5% Accuracy, RH Outputs: 0-10 VDC, Room (R) Infinity Enclosure (Beige) with LCD, Made in USA.
ACI A/RH5-R-LCD-010 : Room Relative Humidity Sensor, 5% Accuracy, RH Outputs: 0-10 VDC, Room (R) Infinity Enclosure (Beige) with LCD, Made in USA The ACI Relative Humidity with LCD utilizes a thermoset polymer capacitive sensing element with integral hydrophobic filter to deliver a proportional analog current or voltage output with long term reliability. The styling of the white, wall mounted enclosure with hinged cover makes it suitable for use in a wide variety of applications. The ACI RH LCD series products can be powered with either an AC or DC supply voltage and features a large, backlit display which improves the overall visibility of the display. Other features include onsite field calibration through a single point offset through the programming of the device using the integral keypad. All units must be ordered with one of the supported output signals of 4-20 mA, 0-5 VDC, or 0-10 VDC The applications for the ACI RH Room Series include: Humidification and Dehumidification: These sensors can be used in systems that control humidity levels, ensuring optimal conditions for comfort or specific processes. Monitoring Indoor Space Humidity: The sensors provide continuous monitoring of humidity levels in indoor spaces, allowing for adjustments and maintaining a comfortable environment. Clean Rooms: In clean room environments, precise humidity control is crucial for maintaining the integrity of sensitive processes and materials. Hospitals: The RH room sensors can be used in hospitals to monitor and control humidity levels, contributing to patient comfort and preventing the growth of harmful microorganisms. Process Control: Industries that rely on specific humidity levels for manufacturing or other processes can benefit from these sensors for accurate monitoring and control. Laboratories: Research and testing laboratories often require precise humidity control to ensure accurate results and maintain the integrity of samples. Museums: Maintaining proper humidity levels is essential for preserving delicate artifacts and artworks in museums.Schools and Office Buildings: The sensors can help create a comfortable and productive environment for students and employees by regulating humidity levels. Data Centers: Data centers need to maintain stable humidity levels to prevent equipment damage and ensure optimal performance. ESD (Anti-Static) Control: In environments sensitive to electrostatic discharge, monitoring and controlling humidity can help mitigate ESD-related risks. Specifications RH Supply Voltage (Reverse Polarity Protected): 4-20 mA: 250 Ohm Load: 15 - 40 VDC / 18 - 28 VAC | 500 Ohm Load: 18 - 40 VDC / 18 - 28 VAC 0-5 VDC: 12 - 40 VDC / 18 - 28 VAC | 0-10 VDC: 18 - 40 VDC / 18 - 28 VAC RH Output Signal: 2-wire: 4 - 20 mA (Factory Default) | 3-wire: 0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable) RH Measurement Range: 0-100% Operating RH Range: 0 to 95% RH, non-condensing RH Stability | Repeatability | Sensitivity: Less than 2% drift / 5 years | 0.5% RH | 0.1% RH Datasheets ACI Room Humidity Sensor with LCD Data Sheet ACI Room Humidity Sensor with LCD Install Sheet
Humidity Sensors Automation Components, Inc.
ACI (Automation Components Inc) - Shop By Brand
A physical wiring diagram for the human immune system
Buy Clean Room Temperature Indicator, Humidity Sensor
Humidity Sensors Automation Components, Inc.
ACE Instruments
HUMIDITY HUMIDITY. Kele Carries Nine Brands to Meet Your Sensing
Humidity Temperature Indicator(AI-RHT)
ACI (Automation Components Inc) - Shop By Brand
Humidity Sensors Automation Components, Inc.
Frontiers Peripheral Sensory Organs Contribute to Temperature
Cleanrooms